The Fluke 975 AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld device. Use the Fluke 975 to optimize HVAC ventilation settings for ASHRAE 62 recommendations, actively monitor conditions that promote a productive environment, and quickly and accurately address occupant comfort complaints the first time.
The Fluke 975 measures:
Use the Fluke 975 AirMeter test tool to:
Features:
The Fluke 975 offers an unparalleled featureset for HVAC and facilities technicians, helping them work more quickly and accurately, with the ease of use and durability customers expect from a Fluke meter.
Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
Measured Specifications | ||
Temperature | Range | -20 °C to 50 °C (-5 °F to 122 °F) |
Display resolution | 0.1 °C (0.1 °F) | |
Accuracy | ± 0.9 °C/± 1.62°F from 40 °C to 60 °C ± 0.5 °C/± 1.00°F from 5 °C to 40 °C ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C |
|
Relative humidity | Range | 10 % to 90 % RH, non-condensing |
Display resolution | 1% | |
Accuracy | ± 2 % RH (10 % RH to 90 % RH) | |
Air velocity | Range | 50.0 fpm to 3000 fpm 0.25 m/sec to 15 m/sec |
Display resolution | 1 fpm (0.005m/sec) | |
Accuracy | ±4 % or 4 fpm* ±4 % or 0.02 m/sec* whichever is greater *Accuracy specification only valid for velocity readings above 50 fpm. |
|
C0 | Range | 0 to 500 ppm |
Display resolution | 1 ppm | |
Accuracy | ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH |
|
C02 | Range | 0 to 5000 ppm |
Display resolution | 1 ppm |
|
Accuracy | Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm | |
Calculated Specifications | ||
Dew point temperature | Range | -44 °C to 50 °C, (-47 °F to 122 °F) |
Display resolution | 0.1 °C (0.1 °F) | |
Accuracy | ± 1 °C when temp: -20 °C to 50 °C RH: 40 % to 90 % ± 2 °C when temp: -20 °C to 50 °C RH: 20 % to 40 % ± 4 °C when RH: 10 % to 20 % |
|
Wet bulb temperature | Range | -16 °C to 50 °C, (3 °F to 122 °F) |
Display resolution | 0.1 °C, (0.1 °F) | |
Accuracy | ± 1.2 °C when RH: 20 % to 90 % temp: -20 °C to 60 °C ± 2.1 °C when RH: 10 % to 20 % |
|
Volume flow rate (in a duct) | Range | 0 to 3,965 M3/m, (0 to 140,000 cfm) |
Display resolution | 0.001 M3/min, (1 cfm) | |
Accuracy | N/A: The volume flow calculation will be a simple average of the data points times the duct area | |
% outside air (based on temperature) | Range | 0 to 100% |
Display resolution | 0.1 | |
% outside air (based on CO2) | Range | 0 to 100 % |
Display resolution | 0.1 % N/A | |
General Specifications | ||
Operating and storage temperature | -20 °C to 50 °C (-4 °F to 122 °F) | |
Humidity | 10 % to 90 % (non-condensing) | |
Altitude | Up to 2000 m (6562 ft) | |
Shock and vibration | MIL-PRF-28800F: Class 2 | |
Multi-language interface | English, French, Spanish, Portuguese and German | |
Battery | Rechargeable Li-Ion (primary), three-AA (backup) | |
Data logging | 25,000 records (continuous), 99 records (discrete) |