Your shopping cart is empty!
Availability: กรุณาสอบถามค่ะ
LAQUA DS-70 series measures Conductivity, Resistivity, Salinity, TDS and Temperature simultaneously and the Model DS-72 complies with industrial pharmacopoeias standard (JIS, USP, EP, JP and CP).
The meters’ auto diagnostic function allows the user to make sure that the instruments will always give high performance and reliable measurements. Fully GLP/GMP compliant, the LAQUA can be connected to an external printer. To ensure traceability all results are recorded together with sample name, user ID and calibration information.
We offer a comprehensive range of conductivity electrodes adapted to all type of application and sample. Recognised for their stability and longevity, HORIBA’s electrodes provide accurate measurement in all conditions.
LAQUA’s large capacitance touch screen panel:
Functions:
Specifications:
Measurement method |
2 AC bipolar method |
|
Measurement range |
Cell constant 100 m-1:0.000 mS/m~19.99 S/m |
|
Resolution |
0.05% of full scale |
|
Repeatability |
±0.5% ±1 digit |
|
Change unit |
○ |
|
Distilled water temperature conversion |
○ |
|
Periodical check |
× |
|
P/EP/USP/CP Pharmaceutical water aplication |
× |
|
Measurement method |
Conversion from conductivity value |
|
Measurement range |
0.00~80.00 PPT(0.000%~8.000%) |
|
Resolution |
0.01 PPT(0.001%) |
|
Salt concentration calibration |
○ |
|
Resistivity |
Measurement method |
Conversion from conductivity value |
Measurement range |
Cell constant 100 m-1:0.00 Ω・m~199.9 kΩ・m |
|
Resolution |
0.05% F.S. |
|
Repeatability |
±0.5%F.S.±1 digit |
|
Measurement method |
Conversion from conductivity value |
|
Measurement range |
0.01 mg/L ~100 g/L |
|
Resolution |
0.01 mg/L |
|
Measurement range |
0.0~100.0℃(-30.0~130.0℃) |
|
Resolution |
0.1℃ |
|
Repeatability |
±0.1℃±1 digit |
|
Input/output |
Input(CH) |
1 |
USB peripherals (Communication with PC)*1 |
○ |
|
USB host(USB memory) |
× |
|
RS-232C(Printer/PC) |
○ |
|
Analog out put |
× |
|
Data |
Memory number |
999 |
Interval memory |
○ |
|
ID input |
○ |
|
Data search |
× |
|
Display |
Display |
Custom LCD |
Multilanguage display |
× |
|
Function |
Navigation function |
× |
User gide |
× |
|
Graf display |
× |
|
Printer connectivity(GLP/GMP) |
○ |
|
Custom printing function |
× |
|
Temperature compensation(Auto/manual) |
○ |
|
AutoHold function |
○ |
|
AutoHold setting |
× |
|
Register operator |
× |
|
Security(pass word) |
○ |
|
Version up function |
○ |
|
Ambient temperature |
0 ℃ ~ 45℃ |
|
Power |
AC adaptor 100 ~ 240 V 50/60 Hz |
|
Demensions |
170(W)×174(D)×73(H)mm(Excluding electrode stand and AC adaptor) |
|
Power consumption |
Approx. 0.7 VA |
|
Mass of main unit |
Approx .500 g |