0
รวม 0.00 ฿
 x 

Your shopping cart is empty!

รวม 0.00 ฿

FREE DELIVERY !

3,000 บาทขึ้นไป*

Technical Support

ทดลองสินค้าหน้าร้าน บริการหลังการขาย

OPEN ( MON-SAT )

8.00-17.30(จ-ศ) 9.00-15.30(เสาร์)

เครื่องวัดความเข้มแสง

  • Light Meters

    Light Meter

     

    How Light Meters Work

    Most meters consist of a body. a photo cell has energy. This energy is transferred by the photo cell into electric current; the amount of current generated depends on the amount of light striking the cell. The meter then reads the electrical current and calculates the appropriate value of either Lux or foot-candles.

    A key thing to remember about light is that it is usually made up of many different types (colors) of light at diffrent wavelengths. The reading, therefore, is a result of the combined effects of all the wavelengths. A standard color can be referred to as color temperature and is expressed in degress Kelvin. The standard color temperature for calibration of most light meters is 2856 degrees Kelvin which is more yellow than pure white.

    Different types of buids burn at different color temperatures. Sper Scientific meter readings will, therefore, vary with different light sources of the same intensity. This is why some lights seem "harsher" than others. See the chart to the left for suggested lighting levels for various applications.

    Light Meter Units of Measure

    Light can be quantified in many ways, i.e., Lux, Lumens, foot-candles,candle power, candelas, and so on. The two most popular scales are Lux, which is the European measure,and foot-candles, which is the U.S. scale. Lux is a unit of illumination of one square meter which is one meter away from a uniform light source. 1 candela = 1 Lux. Foot candles are a unit of illumination of one square foot which is one foot away from a uniform light source. 

    Light Measurement Conversion Factor

    Abbreviations:
    FC-Footcandle, Lux-Lux, Lumen-Lumen

    Since: 1 Lumen/sq ft, and 1 Lux=1 Lumen/sq meter
    and: 1 square ft=0.0929 sq meter
    then: 1 Lux=0.0929 FC, and 1 FC=10.76 Lux

    All models have a fast and accurate response, and are CE approved. The sensors are cosine and color corrected and hermetically sealed to ensure long term stabillty. These meters come ready to use with probes, 9V battery, carrying case, instructions, and a 5-year warranty.

    Convenient Lighting Levels for Varying Applications

    Offices

    100 to 300

    Lux

    General workrooms, corridors, stairs and restrooms

    300 to 750

    Lux

    Conference and computer rooms

    750 to 1500

    Lux

    Technical offices, rooms for drawing and calculating

    Factories

    300 to 750

    Lux

    Winding, steel work and welding

    750 to 1500

    Lux

    Inspection, welding, heavy machinery operation

    1500 to 3000

    Lux

    Inspection and testing operations, selection areas, machine tool areas

    Schools

    75 to 300

    Lux

    Lecture rooms, assembly halls, corridors, stairs and toilets

    200 to 750

    Lux

    Classrooms, demonstration rooms, gymnastics

    300 to 1500

    Lux

    Precision drawing rooms, experimental laboratories, libraries and reading rooms

    Shops

    120 to 500

    Lux

    Stairs, elevators, toilets and corridors

    500 to 1000

    Lux

    Display windows and sales areas

    4000 to 8000

    Lux

    Jewelers and goldsmiths

     

     

     

     

     

     

     

     

     

     

     

     

    Sper Scientific light meters have been checked and calebrated using NIST traceable light sources and standards. The light source is a color correct buid that burns at 2856 degrees Kilvin. The meters have a 5-year warranty. they are used in many applications, from testing the reflectance of porcelain pigments in a QC lab to pharmaceutical degradation studies.

    To convert from

    into

    multiply by

    Lux

    Candela steradian

    1.0

    Lumens

    Candle power (spherical)

    0.07958

    Lumens

    Watts

    0.0015

    Lumens per square centimeter

    Lamberts

    1.0

    Lumens per square centimeter

    Lux

    10000

    Lumens per square centimeter

    Phots

    1.0

    Lumens per square foot

    Foot candles

    1.0

    Lumens per square foot

    Foot lamberts

    1.0

    Lumens per square foot

    Lumens /Square meter

    10.76391

    Lumens per square foot

    Lux

    10.76396

    Lumens per square meter

    Foot candles

    0.0929

    Lumens per square meter

    Lumens/Square foot

    0.0929

    Lumens per square meter

    Phots

    0.0001

    Lumens per square meter

    Lux

    1.0

    Lux

    Foot Candles

    0.0929

    Lux

    Lumens/square meter

    1.0

    Lux

    Phots

    0.0001

     

     

    .

  • ความหลากหลายของเครื่องวัดความเข้มแสงกับการเลือกใช้งาน

    ความหลากหลายของเครื่องวัดความเข้มแสงกับการเลือกใช้งาน

    เครื่องวัดความเข้มแสง คือเครื่องมือที่ใช้วัดค่าปริมาณของแสงที่เกิดขึ้นตามธรรมชาติหรือแสงที่เราสามารถมองเห็นและแสงที่เกิดจากการประดิษฐ์ขึ้น มีหน่วยวัดค่าเป็น ลักซ์ (LUX) และ ฟุตแคลเดิล (Foot Candle) โดยเครื่องวัดค่าความเข้มแสงในปัจจุบันถูกออกแบบมาให้สามารถใช้งานได้หลากหลาย มีความรวดเร็วในการวัด สามารถพกพาได้สะดวกและมีความแม่นยำสูง ซึ่งเหมาะกับการวัดใน โกดัง, โรงงานอุตสาหกรรม, อาคารสำนักงาน, ร้านอาหาร, โรงเรียน, ห้องสมุด, โรงพยาบาล, การถ่ายภาพ, วิดีโอ, โรงจอดรถ, พิพิธภัณฑ์หอศิลป์, สนามกีฬา, การรักษาความปลอดภัยอาคาร เป็นต้น

    เครื่องวัดความเข้มแสง ยังสามารถเลือกใช้งานให้ตรงกับชนิดของแสงที่ต้องการวัดได้อีกด้วย โดยเครื่องวัดค่าความเข้ม แสง ที่สามารถเลือกชนิดแสงได้ ที่นิยมใช้งานในปัจจุบันมีดังนี้

    1.เครื่องวัดความเข้มแสง LED เป็นเครื่องมือที่ออกแบบมาให้วัดความเข้ม แสง LED โดยตรง ซึ่งสามารถเลือกชนิดของสี LED ได้

     

     

     

    2.เครื่องวัดความเข้มแสงทั่วไป เป็นเครื่องมือที่ออกแบบมาให้วัดความเข้ม แสง ทั่วไปตามสำนักงาน , ห้องเรียนและโรงงาน

     

     

Contact Us