The Kimo Kigaz 300 PRO features 4 interchangeable O2, NO, NO2 or SO2, and CO - H2 sensors along with a built in printer.
Features:
Specifications:
Kigaz 300 PRO Technical Features |
|||||
GAS |
- Autozero in the flue |
Flue gases CO and CO2, |
Interchangeable sensors: |
Excess air Losses |
Efficiency > 100 percent |
PRESSURE |
Differential pressure measurement |
High accuracy draft measurement with autozero by solenoid valve |
Measurement of the suction pump flow |
- |
- |
temp. |
Ambient temp. |
Flue gas temp. |
Delta temp. |
DHW temp. |
Dew point temp. |
OTHER FUNCTIONS |
15 programmed combustibles |
Adding 5 combustibles by the user |
Automatic measurements |
Opacity index |
- |
Combustible list - Sahara / Fos sur Mer Nat. Gas, Natural Gas (Groningen), North Sea / Russia Nat. Gas, LPG, Propane, Butane, Heavy Oil, Light Oil, Coke gas, Bituminous coal, Hard coal, Bio fuel 5 percent, Wood 20 percent, Wood chip 21 percent, Pellet 8 percent Specifications |
Kigaz 300 PRO Measuring Range |
|||||
Parameter |
Sensor |
Measuring range |
Resolution |
Accuracy* |
T90 response time |
O2 |
Electro-chemical |
0 percent - 21 percent |
0.1 percent vol. |
+/-0.2 percent vol. |
30 s |
CO |
Electro-chemical |
0 - 8000 ppm |
1 ppm |
0 - 200 ppm : +/-10 ppm |
30 s |
NO |
Electro-chemical |
0 - 5000 ppm |
1 ppm |
0 - 100 ppm : +/-5 ppm. |
30 s |
NOx |
Calculated ** |
0 - 5155 ppm |
1 ppm |
- |
- |
NO2 |
Electrochemical |
0 - 1000 ppm |
1 ppm |
0 - 100 ppm : +/-5 ppm. |
80 s |
SO2 |
Electrochemical |
0 - 5000 ppm |
1 ppm |
0 - 100 ppm : +/-5 ppm. |
80 s |
CO2 |
Calculated ** |
0 - 99 percent vol |
0.1 percent vol |
- |
- |
CH4 |
Semiconductor |
0 - 10000 ppm |
1 ppm |
+/-20 percent of full scale |
40 s |
Flue gas temp. |
K thermocouple |
-100 - +1250 deg. C |
0.1 deg. C |
+/-1 deg. C |
45 s |
Ambient temp. |
Internal NTC |
-20 - +120 deg. C |
0.1 deg. C |
0.1 deg. C |
45 s |
Ambient temp. |
Pt100 (1/3 Din ext. probe) |
-50 - +250 deg. C |
0.1 deg. C |
+/-0.3 percent of the measured value +/-0.25 deg. C |
30 s |
Dew point temp. |
Calculated ** |
0 - +99 deg. Ctd |
0.1 deg. C |
- |
- |
DHW temp. |
TcK (ext. probe) |
-200 - +1300 deg. C |
0.1 deg. C |
+/-1 deg. C |
- |
Draft |
Piezoelectric |
-10 - +10 Pa |
0.1Pa |
-100 - -10 Pa : +/-2 Pa |
- |
Differential pressure |
Piezoelectric |
-20 000 - +20 000 Pa |
1 Pa |
-20 000 - -751 Pa : +/-(-0.5 percent of measured value +4.5 Pa) |
- |
Losses |
Calculated ** |
0 - 100 percent |
0.1 percent |
- |
- |
Flue gas velocity |
- |
0 - 99.9 m/s |
0.1 m/s |
- |
- |
Excess air λ |
Calculated ** |
1 - 9.99 |
0.01 |
- |
- |
Lower Efficiency ηs |
Calculated ** |
0 - 100 percent |
0.1 percent |
- |
- |
Higher Efficiency ηt(condensation) |
Calculated ** |
0 - 120 percent |
0.1 percent |
- |
- |
Opacity index |
ext. instrument |
0 - 9 |
- |
- |
- |