Fluke 566 Infrared and Contact Thermometers

Availability: กรุณาสอบถามค่ะ

The Fluke 566 two-in-one contact and non contact thermometer can stand up to tough industrial, electrical, and mechanical environments.
สอบถามเกี่ยวกับสินค้า
Product Tags

เครื่องวัดอุณหภูมิ FLUKE 566

 

Fluke 566 Infrared and Contact Thermometers

Features:

  • Measure -40 °C to 800 °C /-40 °F to 1472 °F (568) or -40 °C to 650 °C/-40 °F to 1202 °F (566)
  • Easily access advanced features with the soft-key buttons and dot-matrix display
  • Measure smaller objects from further away, with a distance-to-spot ratio of 50:1 (568) or 30:1 (566)
  • Compatibility with all standard miniconnector Type-K thermocouples allow you to preserve your thermocouple investments
  • Confidently measure a wide variety of surfaces, with the adjustable emissivity feature, including a built-in material table
  • Capture multiple points of data (up to 99 with the 568, and 20 with the 566), for downloading and recalling later
  • Easily adapt to lighting conditions with 2 levels of backlight
  • Audible and visual alarms instantly alert you to measurements outside of your set limits
  • Quickly identify problems with the MIN, MAX, AVG, and DIF functions
  • Make contact thermometer measurements right away with the included Type-K thermocouple bead probe
  • Confidently troubleshoot equipment with 1 % measurement accuracy
  • Versatile interface with 6 languages from which to choose
Product Specifications
Infrared temperature range -40 °C to 650 °C (-40 °F to 1202 °F)
Infrared accuracy < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);

> 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater

Display resolution 0.1 °C / 0.1 °F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 msec
Thermocouple Type-K input temperature range -270 °C to 1372 °C (-454 °F to 2501 °F)
Thermocouple Type-K input accuracy -270°C to -40°C: ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F))
-40°C to 1372°C: ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater
D:S (distance to measurement spot size) 30:1
Laser sighting Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage with date/time stamp 20 points
PC interface and cable None
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix 98 x 96 pixels with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable Celsius and Fahrenheit Yes
Power 2 AA/LR6 Batteries
Battery life If used continuously: Laser and backlight on,12 hours; laser and backlight off, 100 hours
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-40 °F to 140 °F)
Bead thermocouple Type-K range -40 °C to 260 °C (-40 °F to 500 °F)
Bead thermocouple Type-K accuracy ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F),
typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)