hi96753 hannahi96753 hanna

Chloride Portable Photometer HI96753

16,800.00 ฿

Availability: กรุณาสอบถามค่ะ

Chloride ions are one of the major inorganic anions in water and wastewater.
สอบถามเกี่ยวกับสินค้า
Product Tags

HI96753

Chloride Portable Photometer

  • CAL CHECK™
  • User calibration
  • Certified calibration and verification standards
  • BEPS (Battery Error Prevention System)
  • TIMER function
  • Auto shut-off
  • GLP Features

Chloride ions are one of the major inorganic anions in water and wastewater. Although high concentrations of chloride in water are not known to be toxic to humans, its regulation is mainly due to adverse effects on taste. It is essential to monitor chloride concentrations in boiler systems to prevent metal parts from being damaged. In high levels, chloride can corrode stainless steel. The level of chloride concentrations in boiler and cooling towers varies from small quantities to very high levels. Furthermore high levels of chloride can be toxic to plant life.

Chlorides are the salts of hydrochloric acid with a metal. Some common examples are sodium chloride (NaCl), ammonium chloride (NH4Cl), calcium chloride (CaCl2), and magnesium chloride (MgCl2).  When dissolved in water, these salts produce chloride ions, Cl-.

The HI 96753 meter measures the chloride content in water and wastewater samples. This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.

Order Information:
HI 96753
is supplied with sample cuvettes with caps (2), 9V battery and instruction manual.
HI 96753C
includes HI 96753 photometer, sample cuvettes and caps (2 ea.), instrument quality certificate, instruction manual and rigid carrying case.

Range   0.0 to 20.0 mg/L
Resolution   0.1 mg/L
Accuracy   ±0.5 mg/L ±6% of reading @ 25°C
Light Source   LED
Light Detector   Silicon photocell with narrow band interference filter @ 466 nm
Power Supply   (1) 9V battery
Auto-off   After 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder.
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)
Method   Adaptation of the mercury(II) thiocyanate method.
 