The Biochrom Libra S22 is a simple-to-use instrument with advanced performance, incorporating Xenon lamp technology for longer source lifetime and lower maintenance costs. A further benefit of this design is Reference Beam Compensation (RBC) to remove optical noise and improve signal to background measurements.
In addition to measuring absorbance, transmittance and concentration, wavelength scan (with zoom), absorbance changes with time, reaction rate determinations and standard curves can be displayed as graphics and printed out. User defined equations can be entered using multi-wavelength mode and up to 18 methods can be saved in separate operator folders.
The S22 can be operated with Resolution software, a powerful yet intuitive PC software for data acquisition and analysis.
Designed for regulatory compliance
This instrument is ideal for industrial laboratories seeking GLP, IQ/OQ certification test plans and output to LIMS. The on-board self test diagnostics for instrument performance validation may be used in conjunction with the Qualification and Performance Verification Logbook (provided with the instruments) so that an ongoing record of instrument performance over time may be kept for GLP purposes. For 21CFR part 11 compliance, Resolution CFR software is required (optional).
Wide range of accessories
See Biochrom Libra Accessories for order codes for:
Ordering Information | Order Code |
Biochrom Libra S22 Visible Spectrophotometer | 80-2115-20 |
Resolution Lite | 80-7100-30 |
Resolution | 80-7100-31 |
Resolution Life Sciences | 80-7100-32 |
Resolution CFR | 80-7100-33 |
Serial Cable | 80-2105-97 |
IQ/OQ Documentation | 80-5000-19 |
Spare Parts
80-2109-50 Qualification and performance verification logbook
Order codes for spectrophotometric cells and cuvettes
Technical specifications are shown below. Optional accessories are marked *
Technical Specifications
Specification | Data |
---|---|
Type | UV/Vis |
Wavelength Range | 190 - 1100nm |
Wavelength Accuracy (+/-) | 1nm |
Wavelength Reproducibility (+/-) | 0.5nm |
Lamp Source | Xenon (PTR) |
Beam | Split Beam |
Optical System | Reference Beam Compensation |
Bandwidth | |
Detector | Dual Solid State Silicon photodiode |
Photometric Range | -3.000 to 3.000A, -9999 to 9999 conc. units, 0.1 to 200%T |
Stray Light | <0.05%T at 340nm |
Zero Stability | ± 0.002A/h at 0A after warm up |
Baseline Flatness | n/a |
Measurement Type | Fixed Wavelength, Abs/%T, Abs ratio, Abs difference, concentration (standard curve), concentration (factor), multiwavelength, kinetics, Life Science Methods, cell density |
Cell Compatibility | Cuvette, Flow Cell*, Microcell*, Variable Pathlength Cell* |
Other Sample Containers | n/a |
Cell Holder | Built in 8 cell changer, 4 position cell changer*, 6 and 8 position heated cell changers*, single cell holder* |
Accessory Options | Flow cell*, Sipper*, Cylindrical Cell holder*, Autosampler capability* |
Method Storage | Up to 18 |
Compliance | 21 CFR part 11*, IQ/OQ* |
Data Output | Print*, Export to PC*, PC Control* |
Display | Graphical LCD |
Data Interface | serial, parallel |
Languages | English, French, German, Italian, Spanish, Russian |
Power Requirement | 90-265V, AC, 50/60Hz, 80VA |
Weight | 13Kg (28.6lb) |
Dimensions (WxDxH) | 51 x 37 x 23 cm (20 x 14.6 x 9.1 inches) |
Noise | ± 0.001A near 0A and ± 0.002A near 2A at 600nm |
Photometric Accuracy | +/- 0.5% or +/-0.003A to 3A at 546nm |
Photometric Reproducibility | 0.5% of absorbance value |
Spectral Scanning | Yes (up to 900nm) |