Fully featured and priced right, the testo 310 residential combustion analyzer provides exceptional value and complete capabilities in combustion testing and furnace efficiency. With its capability to perform both basic, or more complex flue gas analysis, maintenance or safety checks, or confirm furnace efficiency, the fully featured testo 310 combustion analyzer delivers more combustion parameters. The stainless steel probe and cone-stop is perfect for residential, and boiler applications. The 310 can be used for accurate heating adjustments, so you can get it right the first time - every time. With five different fuels to select from (Natural Gas, Propane, Fuel Oil 2, Biomass 5%, Wood 20%), it provides the flexibility you need for your tuning opportunities. With an optional printer kit available, you are able to keep records of all readings taken.
Measures
- O2, CO (with built-in NOx filter), CO2
- Undiluted CO (CO air free)
- Ambient CO
- Draft & Pressure
- Temperature (flue & ambient)
- Combustion/flue gas efficiency & excess air
Delivery Scope
testo 310 combustion analyzer, lithium battery, sensors, probe with cone, hose, silicon tubing (for pressure), extra particulate filters (5), AC power supply (USB), pressure plugs (5), calibration certificate, & case.
Technical Data:Temperature - Type K TC
- Measuring range: -4° to 212 °F / -20 to +100 °C
- Accuracy: ±2 °F / ±1 °C
- Resolution: 0.1 °F / 0.1 °C
- Reaction time: < 50 sec
Temperature (ambient temperature)
Temperature - Type J TC
- Measuring range: 32° to 752 °F / 0 to +400 °C
- Accuracy
-- ±1.8 °F (32° to 212 °F) / ±1 °C (0 to +100 °C)
-- ±1.5 % of mv (> 212 °F) / ±1.5 % of mv (> 100 °C)
- Resolution: 0.1 °F / 0.1 °C
- Reaction time: < 50 sec
Temperature (flue gas)
Flue gas O₂
- Measuring range: 0 to 21 Vol.%
- Accuracy: ±0.2 Vol.%
- Resolution: 0.1 Vol.%
- Reaction time t₉₀: 30 sec
Flue Gas Draft
- Measuring range: -8 to +8 InH₂O / -20 to +20 hPa
- Accuracy:
-- ±0.01 InH₂O (-1.20 to +1.20 InH₂O) / ±0.03 hPa (-3.00 to +3.00 hPa)
-- ±1.5 % of mv (Remaining Range)
- Resolution: 0.01 InH₂O / 0.01 hPa
Efficiency (calculated)
- Measuring range: 0 to 120 %
- Resolution: 0.1 %
Flue Gas loss (calculated)
- Measuring range: 0 to 99.9 %
- Resolution: 0.1 %
Flue Gas CO₂ calculation (calculated from O₂)
- Measuring range: 0 to CO₂ max (Display range)
- Accuracy: ±0.2 Vol.%
- Resolution: 0.1 Vol.%
- Reaction time t₉₀: < 40 sec
Pressure measurement
- Measuring range: -16 to +16 InH₂O / -40 to +40 hPa
- Accuracy: ±0.2 InH₂O / ±0.5 hPa
- Resolution: 0.1 InH₂O / 0.1 hPa
Flue gas CO (without H₂-compensation)
- Measuring range: 0 to 4000 ppm
- Accuracy
-- ±20 ppm (0 to 400 ppm)
-- ±5 % of mv (401 to 2000 ppm)
-- ±10 % of mv (2001 to 4000 ppm)
- Resolution: 1 ppm
- Reaction time t₉₀: 60 sec
Ambient CO
- Measuring range: 0 to 4000 ppm
- Accuracy
-- ±20 ppm (0 to 400 ppm)
-- ±5 % of mv (401 to 2000 ppm)
-- ±10 % of mv (2001 to 4000 ppm)
- Resolution: 1 ppm
- Reaction time: 60 sec
General technical data
- Dimensions: 8 x 3 x 2 in. / 201 x 83 x 44 mm
- Operating temperature: 23° to 113 °F / -5 to +45 °C
- Display type: LCD
- Display function: Backlit 2-line display
- Power supply: Battery: 1500 mAh, mains unit 5V/1A
- Storage temperature: -4° to 122 °F / -20 to +50 °C
- Weight: (with probe) Approx. 25 oz. / (with probe) Approx. 700 g