Your shopping cart is empty!
รวม 0.00 ฿
Availability: กรุณาสอบถามค่ะ
Applications:
- Flue gas measurement
- Draught measurement
- Gas flow and static gas pressure
- Gas leak detection
- Ambient CO measurement
- Differential temperature measurement
Technical Data:
Memory | 500 readings |
---|---|
Storage temperature | -20 to +50 °C |
Operating temperature | -5 to +45 °C |
Weight | 573 g |
Dimensions | 240 x 85 x 65 mm |
Probe type Type K | |
---|---|
Meas. Range | -40 to +1200 °C |
Resolution | 0.1 °C (-40 to +999,9 °C) 1 °C (> +1000 °C) |
Probe type CO | |
Meas. Range | 0 to 500 ppm |
Accuracy | ±5 ppm (0 to 100 ppm) ±5% of mv (> 100 ppm) |
Resolution | 1 ppm |
Probe type CO2 | |
Meas. Range | 0 to 1 Vol. % 0 to 10.000 ppm |
Accuracy | ±50 ppm or ±2% of mv (0 to 5000 ppm) ±100 ppm or ±3% of mv (5001 to 10000 ppm) |
Probe type Differential pressure | |
Meas. Range | 0 to +300 hPa |
Accuracy | ±0.5 hPa (0.0 to 50.0 hPa) ±1% of mv (50.1 to 100.0 hPa) ±1.5 % of mv (remaining range) |
Resolution | 0.1 hPa |
Probe type Draught measurement | |
Meas. Range | -9.99 to +40 hPa |
Accuracy | ±0.02 hPa or ±5% of mv (-0.50 to +0.60 hPa) ±0.03 hPa (+0.61 to +3.00 hPa) ±1.5% of mv (+3.01 to +40.00 hPa) |
Probe type Exhaust gas loss measurement | |
Meas. Range | 0 to 99.9% |
Resolution | 0.1% |
Probe type Electrochemical measurement CO | |
Meas. Range | 0 to 4000 ppm |
Accuracy | ±20 ppm (0 to 400 ppm) ±5% of mv (401 to 2000 ppm) ±10% of mv (2001 to 4000 ppm) |
Resolution | 1 ppm |
Probe type Electrochemical measurement O2 | |
Meas. Range | 0 to 21 Vol. % |
Accuracy | ±0.2 Vol. % |
Resolution | 0.1 Vol. % |
Probe type Efficiency Measurement (Eta) | |
Meas. Range | 0 to 120% |
Resolution | 0.1% |
Probe type CO2-determination | |
Meas. Range | 0 to CO2 max |
Accuracy | ±0.2 Vol. % |
{tortags,1800,3}
Product Information | |
Datasheet | |
Manual | |
TESTO Catalog |