HI93552R ThermometerHI93552R Thermometer

HI93552R HANNA เครื่องวัดอุณหภูมิ Thermocouple Thermometer

19,800.00 ฿

Availability: กรุณาสอบถามค่ะ

HI93552R HANNA เครื่องวัดอุณหภูมิ Dual Channel K, J, T-Type Thermocouple Thermometer ความแม่นยำสูง ใช้ได้กับโพรบหลายชนิด
สอบถามเกี่ยวกับสินค้า
Product Tags

เครื่องวัดอุณหภูมิ HI93552R HANNA 

Dual Channel K, J, T-Type Thermocouple Thermometer

HI93552R HANNAThe Dual Channel K, J, T-Type Thermocouple Thermometer - HI93552R is a digital, waterproof thermometer. This meter offers high accuracy temperature measurements using a wide variety of interchangeable K-type probes. HI93552R allows users to perform a one-point calibration and to transfer data to a PC or printer with an RS232 output. All readings are displayed on the backlit LCD, along with the high and low temperatures, a channel indicator, temperature units, and a battery indicator upon startup.

Details

The HI93552R is a dual channel J, K, T-type thermocouple thermometer that can be used with a wide variety of K-type probes. This thermometer offers temperature readouts in both degrees Celsius and Fahrenheit. Featuring a one-point calibration, up to ±0.5°C accuracy, PC and printer connectivity, and a backlit LCD, the HI93552R is perfectly suited for high accuracy temperature measurements in the laboratory, field, or dimly lit areas.

Features at-a-glance

CAL Function - The HI93552R can be calibrated at one point in a 0°C ice bath when the probes are interchanged to achieve the highest possible accuracy.

Two Input Channels - The HI93552R can monitor two samples through two independent temperature channels. The display shows the actual, high, and low values of the selected channel (T1, T2 or T1-T2). The desired channel and displayed information can easily be selected using the T1/T2 and DISP key, respectively.

Interchangeable Probes - A wide range of K-type thermocouple probes are available to meet the specific needs of users. Any of the HI766 series of probes can be interchanged with the HI93552R to measure temperature of surfaces, gases, air, liquid, semi-solid samples, and more.

°C/°F Readout - Measurements can be displayed in either degrees Celsius or Fahrenheit. A simple press of the °C/°F button will switch between the scales.

High/Low Function - The maximum and minimum temperature values are continuously monitored and displayed on the lower portion of the HI93552R LCD display during a measurement session. The CLR button clears the high and low values on the LCD display.

HOLD Function - The HOLD button on the face of the meter freezes the display to allow the user time to record readings. Although the display is frozen, the meter continues to internally monitor the temperature and update the high and low measurement values.

Connectivity - The HI93552R features an RS232 output that allows for data transfer to a PC or printer. With the optional HI92000 software, users can easily manage their measurement data or send directly to a printer.

Backlit LCD - The LCD display is equipped with a backlight feature that can easily be activated through the BL button for low or no light conditions. The backlight automatically shuts off after approximately one minute when no buttons are pressed to preserve battery life.

Battery Error Prevention System (BEPS) - The Battery Error Prevention System detects when the batteries become too weak to ensure reliable measurements.

Low Battery Indicator - When the battery level is below 10%, a warning symbol will blink to indicate low battery condition.

Specifications

K Range -200.0 to 999.9°C and 1000 to 1371°C; -328.0 to 999.9°F and 1000 to 2500°F

K Resolution 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (1000 to 1371°C); 0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F); 0.3°F (-328.0 to -250.0°F); 1°F (1000 to 2500°F)

J Range -200.0 to 999.9°C; -328.0 to 999.9°F and 1000 to 1832°F

J Resolution 0.1°C (-200.0 to 999.9°C); 0.1°F (-149.9 to 999.9°F); 0.2°F (-328.0 to -150.0°F); 1°F (1000 to 1832°F)

T Range -200.0 to 400.0°C; -328.0 to 752.0°F

T Resolution 0.1°C (-149.9 to 400.0°C); 0.2°C (-200.0 to -150.0°C); 0.1°F (0.0 to 752.0°F); 0.2°F(-270.0 to -0.1°F); 0.3°F (-328.0 to -270.1°F)

Temperature Accuracy ±0.5°C (-100.0 to 999.9°C); ±1°C (outside); ±1°F (-148.0 to 999.9°F); ±1.5°F (outside) (for 1 year, excluding probe error)

Electrode/Probe HI766 series K-type thermocouple (not included)

CAL Button yes

Backlit LCD yes

RS232 yes

Battery Type/Life 1.5V AA (3) / approximately 500 hours of continuous use (with backlight off); auto-off: selectable after 8 or 60 minutes of non-use (can be disabled)

Environment -10 to 60°C (14 to 122°F); RH max 100%

Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4’’)

Weight 235 g (8.3 oz)

Ordering Information HI93552R is supplied with batteries and instructions.

 