Your shopping cart is empty!
Availability: กรุณาสอบถามค่ะ
Ultrasonic thickness gauge overview:
The model MT180 is a multi-mode ultrasonic thickness gauge. Based on the same operating principles as SONAR, the instrument is capable of measuring the thickness of various materials with accuracy as high as 0.1/0.01 millimeters. The multi-mode feature of the gauge allows the user to toggle between pulse-echo mode (flaw and pit detection), and echo-echo mode (eliminate paint or coating thickness).
Ultrasonic thickness gauge product specifications:
Measuring Range | 0.65-600mm( P-E), 3-30mm (E-E) |
Working Frequency | (2.5-7)MHZ |
Probe Diameter | Standard Probe P5EE is 10mm, Probe N05 is10MM、Probe N07 is 6MM、Probe HT5 is12MM、Probe N02 is12MM |
Min. Pipe Diameter | Φ15mm×2.0mm |
Resolution | 0.1/0.01mm |
Accuracy | ±(0.5%Thickness+0.01)mm |
Display | 4.5 digits LCD with EL backlight |
Single /Scan Mode | Seven measurements readings per second in single point mode, and sixteen per second in Scan Mode |
Probe Calibration | Zero Calibration, Two-Point Calibration |
Velocity Range | 1000-9999m/s |
Unit | Metric/Imperial unit selectable |
Language | English |
Memory | up to 20 files (up to 99 values for each file) of stored values |
Communication Port | USB |
Data Printing | Yes |
Power supply | Two “AA” size, 1.5 Volt alkaline batteries |
Lower Power Comsumption | Yes |
Working Hours | 100h (EL backlight off). |
Operating Temperature | -20℃-+60℃ |
Relative Huminity | ≤90% |
Appearance | ABS Plastic |
Outline | 150mm×74mm×32 mm |
Gross Weight | 1.5 KG |
PC Datapro Software | Yes |
Speech Function | No |
Ultrasonic thickness gauge main functions:
1. Multi-mode: Pulse-Echo mode and Echo-Echo mode.
2. Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials.
3. Transducer models are available for special application, including for coarse grain material and high temperature applications.
4. Probe-Zero function, Sound-Velocity-Calibration function.
5. Two-Point Calibration function.
6. Single point mode and Scan mode. Seven measurements readings per second in single point mode, and sixteen per second in Scan Mode.
7. Coupling status indicator showing the coupling status.
8. Units: Metric/Imperial unit selectable.
9. Battery information indicates the rest capacity of the battery.
10. Auto sleep and auto power off function to conserve battery life.
11. Optional software to process the memory data on the PC.
Standard Configuration
- Main body
- Probe P5EE(5MHz)
- Couplant
- Instrument Case
- Operating Manual
- Alkaline battery AA×2
Optional Configuration
- Probe N05/90° (5MHz)
- Probe N07 (7MHz)
- Probe HT5 (5MHz)
- DataPro Software
- Communication Cable
Product Information | |
Datasheet | |
Manual | |
MITECH Catalog |