Features:
Electrical Specifications | |||
Current measurement dc and ac 10 Hz to 100 Hz | Range | 40 A / 400 A / 2000 A; 1400 ac rms | |
Resolution | 10 mA / 100 mA / 1 A | ||
Accuracy | A: 1.5 % rdg + 15 digits A: 1.5 % rdg + 5 digits |
||
Trigger Level for Inrush | 0.50 A / 5.0 A / 5 A | ||
Trigger Level for Hz Filter OFF | 2.50 A / 2.5 A / 8 A | ||
Trigger Level for Hz Filter ON | 0.50 A / 2.5 A / 8 A | ||
Crest Factor (50/60 Hz) | Range | 40 A / 400 A / 2000 A; 1400 ac rms | |
Crest Factor* | 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A |
||
Current measurement ac 100.1 Hz to 1 kHz | Range | 40 A / 400 A / 2000 A; 1400 ac rms | |
Resolution | 10 mA / 100 mA / 1 A | ||
Accuracy | 10 A : 3.5 % rdg + 15 digits 10 A : 3.5 % rdg + 5 digits |
||
Trigger Level for Inrush | 0.50 A / 5.0 A / 5 A | ||
Trigger Level for Hz Filter OFF | 2.50 A / 2.5 A / 8 A | ||
Trigger Level for Hz Filter ON | 0.50 A / 2.5 A / 8 A | ||
Frequency measurement | Measurement range | 5.0 Hz to 1 kHz | |
Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) | ||
Accuracy – 5.0 Hz to 100 Hz | 0.2 % + 2 counts | ||
Accuracy – 100.1 Hz to 1 kHz | 0.5 % + 5 counts | ||
Trigger level | Refer to current and voltage tables |
*Add 2 % to error spec for CF > 2
General Specifications | |
Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 |
Battery life (with typical usage, backlight off) | 100 hours |
Test leads | Rated to 1000 V |
Weight | .814 kg (1.8 lb) |
Jaw size | 58 mm (2.28 in) |
Dimensions (LxWxD) | 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
Safety rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
Environmental Specifications | ||
Operating temperature | 32 °F to + 122 °F (0 °C to +50 °C) | |
Storage temperature | -4 °F to 140 °F (-20 °C to +60 °C) | |
Operating humidity | 0 to 95 % (non-condensing) | |
Operating altitude | 2000 m | |
Storage altitude | 10,000 m | |
IP rating | 42 (indoor use only) | |
Drop test requirements | 1 m | |
EMI, RFI, EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
|
Temperature coefficients | Current | 0.1 % of reading per °C outside 22 °C to 24 °C |
Voltage | 0.1 % of reading per °C outside 22 °C to 24 °C |
{tortags,2387,3}