เครื่องวัดฟลูออไรด์ HI 739 Checker®HC Handheld Colorimeter - Fluoride High Range

3,100.00 ฿

Availability: กรุณาสอบถามค่ะ

เครื่องวัดฟลูออไรด์ Fluoride Meter > Easier to use and more accurate than chemical test kits. SPADNS method ±0.5 ppm ± 5% of reading accuracy. Large, easy to read digits. Auto shut off ...
สอบถามเกี่ยวกับสินค้า
Product Tags

HI 739

Checker®HC Handheld Colorimeter - Fluoride High Range

 
  •  Easier to use and more accurate than chemical test kits

    SPADNS method   
    ±0.5 ppm ± 5% of reading accuracy
    Large, easy to read digits
    Auto shut off

  • Dedicated to a single parameter

    Designed to work with HANNA’s reagents
    Uses 10 mL glass cuvettes

  • Small size, big convenience

    Weighing a mere 64 g (2.25 oz.), the
    Checker®HC easily fits into the palm of
    your hand or pocket
    Use for quick and accurate on the spot
    analysis
    Single button operation: zero and
    measure
    Operated by a single AAA battery

 

Fluoride is one of the very few chemicals that have been shown to cause significant effects in people through drinking-water. Fluoride has beneficial effects on teeth at low concentrations in drinking-water, but excessive exposure to fluoride in drinking-water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.

Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth it creates low levels of fluoride in saliva, which reduces the rate at which tooth enamel demineralizes and increases the rate at which it remineralizes in the early stages of cavities.

A 1994 World Health Organization expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.

The HI 739 Checker®HC is simple to use. In one vial add 2 ml of Reagent A and 8 ml of Reagent B; gently invert 5 times, and wait 1 minute, then zero the instrument with the vial. After zeroing, remove the vial and add 1 ml of sample, gently invert 5 times, wait 1 minute, then insert the cuvette into the HI 739 Checker®HC and press the read button for results.

 

Order Information:
HI 739 Checker®HC is supplied with sample cuvettes with caps (2), reagents for 4 tests, syringe with tip, pipette, battery and instructions.

 

Specification:

Range

  0.0 to 20.0 ppm
Resolution   0.1 ppm
Accuracy @ 25°C   ±0.5 ppm ± 5% of reading
Light Source   LED @ 575 nm
Light Detector   silicon photocell
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type   (1) 1.5V AAA
Auto-off   after two minutes of non-use and ten seconds after reading
Dimensions   81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight   64 g (2.25 oz.)
Method   adaptation of SPADNS method
 