Your shopping cart is empty!
Availability: กรุณาสอบถามค่ะ
• Auto range and manual range.
• Overrange protection is provided for all ranges.
• Maximum voltage between terminals and earth ground: 600V DC or 600V rms AC
• Operating altitude: max. 2000 meters (7000 ft.)
• Display: 4000 counts with analog bar LCD display
• Maximum value display: 4000 digits
• Polarity indication: automatic; '-' for negative polarity.
• Overrange indication: '0L' or '-0L'
• Converter Rate: 3 times/sec; Bar graph: 30 times/sec.
• Unit indication: function and unit.
• Auto power off time: 15 minute.
• Operating power : 1.5V×3 AAA batteries
• Battery low indication on LCD
• Temperature factor: < 0.1×Accuracy /°C
• Operating temperature: 0°C to 40°C (32°F to 104°F)
• Storage temperature: -10°C to 50°C (10°F to 122°F)
• Dimension: 225×86×33mm
• Weight: approximate 320g(including batteries)
• Safety rating: CAT.III 600V RoHS
Features:
• Display: 4000 counts
• Jaw Opening: Φ40mm/1.6"
• Auto Ranging
• Auto Power Off
• Diode: 3.3V
• Continuity Buzzer: <50Ω
• MAX/MIN
• Relative Measurement
• Data Hold
• Low Battery Display
• Display Backlight
• Work Light
• Segment Bar Graph
• True Root Mean Square
Specification |
Range |
Accuracy |
DC Voltage |
400mV |
+-(0.8%+2) |
|
4V/40V/400V |
+-(0.7%+2) |
||
600V |
+-(0.8%+2) |
||
AC Voltage |
4V/40V/400V |
+-(0.8%+3) |
|
600V |
+-(1.0%+4) |
||
DC Current |
40A/400A/1000A |
+-(3.0%+6) |
|
AC Current |
40A/400A/1000A |
+-(2.5%+6) |
|
Resistance |
400Ω/4kΩ/40kΩ/400kΩ |
+-(0.8%+3) |
|
4MΩ/40MΩ |
+-(1.2%+3) |
||
Capacitance |
40nF/400nF/4µF/40µF/400µF/4000µF |
+-(4.0%+5) |
|
Frequency |
A |
99.99Hz/999.9Hz |
+-(1.5%+5) |
>1kHz |
Take it only as reference |
||
V |
99.99Hz/999.9Hz/9.999kHz |
+-(1.5%+5) |
|
>10kHz |
Take it only as reference |
||
Hz / DUTY |
9.999/99.99/999.9Hz/9.999/99.99/999.9kHz/9.999MHz |
+-(0.5%+2) |
|
Duty Cycle |
0.1%~99% |
+-3.0% |